Richiedi informazioni per questo prodotto ➦


IXXAT CAN-CR120/HV

CAN / CAN FD repeater with screw terminals
and 3 kV galvanic isolation
Product announcement: Available from April 2019

The CAN-CR120/HV is used for galvanic isolation of two segments of a CAN / CAN FD network. As a special feature, the repeater separates a defective segment from the rest of the network, allowing the remaining network to continue working. After the fault has been eliminated, the segment is automatically switched back to the network. The galvanic isolation is provided for the CAN / CAN FD segments as well as for the power supply.

Display Transmit and defective segment (two duo LEDs, one for each segment),
Power (one LED)
CAN bus interface ISO 11898-2 with CAN choke. Two screw terminals.
Available with and without integrated CAN termination.
CAN baudrate Up to 888 kbit/s
CAN FD bus interface ISO CAN FD and nonISO CAN FD
CAN FD baudrate 500 kbit/s (arbitration bitrate) and up to 2 Mbit/s  (flexible data rate)
Delay typ. 175 ns (corresponds to ~35 m bus length)
Power supply 9-36 V DC, typ. 70 mA, max. 100 mA, through terminals
Galvanic isolation 3 kV DC / 1 sec, 1500 V AC / 1 min; CAN 1, CAN 2 and
power supply are galvanically isolated from each other.
Certification CE, FCC
Temperature range  -20 ºC ... +70 ºC
Housing, size Plastic enclosure, 22.5 x 105 x 114 mm
  • Line protection up to 3 kV
  • CAN and CAN FD interfaces in one device
  • Cost savings due to simple wiring
  • Increased system reliability
  • Almost no influence on real-time behavior
1.01.0210.20010 CAN-CR120/HV, with bus termination resistor
1.01.0210.20210 CAN-CR120/HV, without bus termination resistor